Troubleshooting jamming in post fold accumulator and insertion area due to a shuttle motor stall on the DI900 and DI950
Learn how to jamming in the post fold accumulator and insertion area due to a shuttle motor stall on the DI900 and DI950.
Products affected: DI900™, DI950™
Issue
When running the inserter and the shuttle motor is in a stalled state, jams may occur or the item bearing the address may appear behind the insert or return envelope. However, the inserter still runs without detecting a fault because most items coast over the top of the Post Fold shuttle and into the grip of the insert belts, so no error is triggered. The shuttle motor will only restart when the machine is stopped and restarted.Cause
The machine's firmware and board are not compatible.Resolution
To resolve this issue:- Press Stop to stop the inserter.
- Open the covers and remove any jammed material.
- Close all of the covers.
- Press Clear Deck to clear any material in the system.
UPDATED: 29 May 2024