Error 03114100D2 "Mailpiece jam in printer area" on the Connect+ series and SendPro P
Learn how to resolve error 03114100D2 "Mailpiece jam in printer area" on the Connect+ 500W, Connect+ 1000, Connect+ 2000, Connect+ 3000, SendPro P1000, SendPro P1500, SendPro P2000, and SendPro P3000.
Products affected: Connect+® 500W, Connect+® 1000, Connect+® 2000, Connect+® 3000, SendPro® P1000, SendPro® P1500, SendPro® P2000, SendPro® P3000
Issue
Your franking machine displays error code 0311-41-00D2 "Mailpiece jam in printer area" and will not print.
Cause
The franking machine has detected a jam.
Resolution
Clear the mail path:
- Open the front cover.
- Open all blue-handled jam releases.
- Remove all mail pieces and debris from the mail path.
- Blow non-flammable canned air onto the envelope feed deck, working from the left side of the machine to the exit.
- Close all blue-handled jam releases.
- Close the front cover.
UPDATED: 14 August 2021